kinemotion

Validation Status

Document Version: 1.0 Last Updated: 2025-01-13 Status: Pre-validation


Executive Summary

Kinemotion is a pre-validation tool that has not been validated against gold standard measurement systems (force plates, 3D motion capture). While the implementation is technically sophisticated and biomechanically sound, it lacks empirical validation required for research or clinical use.

Bottom Line: Use kinemotion for training monitoring and exploratory analysis. Do not use for research publications, clinical decisions, or any context requiring validated accuracy.


Current Validation Status

What Has Been Done ✅

What Has NOT Been Done ❌


Comparison to Validated Tools

Aspect MyJump (Validated) Kinemotion (Unvalidated)
Force plate validation Yes (ICC=0.997) No
Peer-reviewed study Published 2015 None
Sampling rate 120Hz (iPhone 5s) 30-60fps (video dependent)
Method Manual frame selection Automated landmark tracking
Accuracy vs force plate Bias: 1.1±0.5cm Unknown
Cost ~$12 app Free (open source)
Expertise required Low (frame selection) None (fully automated)
Use in research Yes (widely cited) No (not validated)

Key Difference: MyJump has been validated against force plates and published in peer-reviewed journals. Kinemotion has not.


Current Validation Efforts (AthletePose3D)

We are currently in Phase 1 of a multi-stage validation study using the AthletePose3D (AP3D) dataset, which contains high-speed athletic movements captured by research-grade multi-camera systems.

🧪 Methodology Highlights

To transition from 2D pixel-based analysis to research-grade 3D kinematics, we are implementing:

  1. Coordinate Normalization: Using Procrustes Analysis (Kabsch Algorithm) to align MediaPipe detections with physical world coordinates (mm).
  2. 3D Joint Angles: Reconstructing anatomical angles (Hip, Knee, Ankle) in 3D space to correct for camera perspective and foreshortening.

For detailed technical analysis of why these steps matter for monocular video and how they are implemented, see the AthletePose3D Methodology Guide.


What Kinemotion CAN Claim

Technical Implementation ✅

Practical Use ✅


What Kinemotion CANNOT Claim

Validation Claims ❌

Accuracy Claims ❌


Known Limitations

1. No Gold Standard Validation

Issue: Never compared against force plates or optical motion capture Impact: Unknown accuracy, cannot make quantitative accuracy claims Mitigation: Validation study planned (see roadmap)

2. MediaPipe Pose Estimation Constraints

Issue: MediaPipe validated for clinical joint angles (Armstrong et al., 2025) but NOT for jump performance metrics Limitations documented in research:

Impact: Tracking quality varies with recording conditions Mitigation: Quality indicators and confidence scores (planned)

3. Lower Sampling Rate

Issue: Typical video (30-60fps) vs validated apps (120-240Hz) Impact: Lower temporal resolution may reduce accuracy for rapid movements Comparison:

Mitigation: Sub-frame interpolation, recommend 60fps minimum

4. Indirect Measurement Method

Issue: Landmarks → CoM estimation → velocity → phase detection Impact: Error propagation through processing pipeline Comparison:

Mitigation: Robust filtering, outlier detection, physics checks

5. No Systematic Bias Correction

Issue: Bishop et al. (2022) showed correction factors needed for time-to-take-off when comparing manual vs automated detection Impact: May have uncorrected systematic bias Example from Bishop 2022:

Mitigation: Correction factors will be derived after validation study


Use Cases & Recommendations

✅ Appropriate Use Cases

1. Training Monitoring

2. Educational Purposes

3. Exploratory Research

4. Self-Monitoring Athletes

❌ Inappropriate Use Cases

1. Research Publications

2. Clinical Decision-Making

3. Talent Identification

4. Legal/Insurance Context

5. Absolute Performance Comparisons


Validation Roadmap

Planned Validation Activities (3 Months)

Phase 1: Internal Consistency (Month 1)

Phase 2: Comparative Validation (Month 2)

Phase 3: Documentation & Publication (Month 3)

Expected Outcomes

What This Will NOT Provide:

Future Validation (When Lab Access Available)

Gold Standard Validation:

  1. Force plate comparison study (n≥20 subjects)
  2. Calculate ICC, bias, limits of agreement
  3. Derive correction factors if needed
  4. Publish in peer-reviewed journal

Target Metrics:

For detailed roadmap, see docs/development/validation-roadmap.md.


To Maximize Accuracy (Based on MediaPipe Literature)

Camera Setup:

Environment:

Athlete:

Avoid:


Frequently Asked Questions

Q: Can I use kinemotion for my research study?

A: Not as a validated measurement instrument. You can:

Do not:


Q: How does kinemotion compare to MyJump?

A:

If you need validated measurements, use MyJump or similar validated apps.


Q: Why should I use kinemotion instead of MyJump?

A: You probably shouldn’t if you need validated accuracy. Use kinemotion if:


Q: Can I track my own training progress with kinemotion?

A: Yes! For personal use tracking relative changes over time, kinemotion is appropriate. Just understand:


Q: When will kinemotion be validated?

A:


Q: Can I cite kinemotion in my paper?

A: You can cite the software repository, but:

Proper citation:

Kinemotion (version X.X.X) [Software]. (2025). Retrieved from https://github.com/KinemotionInc/kinemotion

Note: Kinemotion is experimental software not validated against force plates.
Measurements should be interpreted with caution.

Contact & Contributions

Report Issues

If you discover accuracy issues or unexpected behavior:

Contribute to Validation

If you have access to validation equipment (force plates, motion capture):

Stay Updated


References

Validation Literature

Biomechanics Theory

Methodological Standards


Document Changelog

Version 1.0 (2025-01-13):